L-478DR: Updating the PocketWizard MiniTT1/FlexTT5 firmware and setting a transmitting radio to use with the meter
L-478DR: Correction for L-478DR Operating manual 5-3-3. Using the Power Control Settings, Page 40.
L-478D/DR: Upgrading Meter Firmware. IMPORTANT INFORMATION FOR MAC AND PC USERS.
L-478D/DR: Battery operation
L-478D/DR Bundle: Read Me First
DTS and L-478 Firmware Release Note

L-478DR: Updating the PocketWizard MiniTT1/FlexTT5 firmware and setting a transmitting radio to use with the meter

  • PocketWizard MiniTT1 and FlexTT5 radios must be upgraded to the latest firmware to work with the Sekonic L-478DR. Firmware upgrades are performed using the PocketWizard Utility (see download instructions below). Using the PocketWizard Utility, click on “Check for Updates” and follow the directions presented.

  • To ensure the L-478DR is exclusively controlling the power level of remote flashes, the on-camera MiniTT1 or FlexTT5 should be set to “No Change (Trigger Only)” mode. This will allow the meter to be the master power controller, and make sure the camera triggers the remote flashes but does not change their power levels.

Using the PocketWizard Utility, follow these steps:

  1. Click the “Advanced Mode” check box located on the bottom left to reveal all available options and tabs
  2. Select the FLASH tab
  3. In the SPEEDLIGHT section, click the drop down and select “No Change (Trigger Only)
  4. Click “Apply Changes” to set the radio.

Download Instructions - Get the PocketWizard Utility here, and install it on your computer: http://www.pocketwizard.com/support/downloads/

For more information on advanced uses of ControlTL radios, visit http://wiki.pocketwizard.com/

Correction for L-478DR Operating manual 5-3-3. Using the Power Control Settings, Page 40.

5-3-3. Using the Power Control Settings
Set power levels of remote flashes connected to PocketWizard ControlTL receivers to create lighting ratios.

1. Set the T (shutter speed) and ISO sensitivity values desired in the Measuring screen

2. Touch the Measuring mode icon to open the Measuring Mode Selection screen, then touch
the icon to activate Radio Triggering Mode and return the screen view to the Measuring
screen (See P25 for details.).

3. Touch the (Wrench) Icon    then Radio CH/Zone and select the Standard and ControlTL channels and zones that match the ones set on the ControlTL receivers connected to the off-camera flashes you are using. Touch “OK” to active channels and Zones and return to the measuring screen. . (See P39 for details.)

4. Touch the Power Control icon    to display the Power Control screen.

  1. Touch one of the ABC ControlTL® Zone buttons at the bottom to activate power control for that zone.
  2.  Touch the +/- icons or slide finger up/down on the slider to set the power level value you desire..
  3. Press the Measuring button on the side of the meter to fire the flash at the set power level and observe the F-value (f-stop) above the Zone button.
  4. Make power adjustments as necessary to obtain the desired F-stop.
  5. Touch the current Zone button to switch OFF the Zone. Then next Zone button to begin selecting power level
  6. Repeat “b” through “e” to Set Zone B and Zone C as desired.

5. After the power levels have been set for each ControlTL Zone (A, B, C),  active all Zones and touch the Radio Triggering Mode icon to return to the Measuring screen.

6. Press the Measuring button on the side of the meter to fire all flashes at values set and observe the F-value (f-stop) for exposure.

7. Make adjustments in T (shutter speed) or ISO while observing the Percentage of Flash value and/or color bars on the analog scale to achieve the desired flash-ambient ratio  (See page 41)

8. Transfer settings to camera. With a PocketWizard MiniTT1 or FlextT5 attached to the camera and set the proper channel, press the shutter button to take the picture.

Notes:
If the flash ratio set in the Power Control Screen does not produce a desired result, press the Power Control Icon and repeat the power control steps under point 4. Be sure to return to the Measuring screen before firing all flashes for the exposure measurement. If all flashes are fired while in the Power Control Screen, all Zones will measure this level and all zone f-numbers will display the same f-number.

L-478D/DR: Upgrading Meter Firmware

APPLE MAC OWNERS USING CURRENT DTS SYSTEM-- EXTREMELY IMPORTANT!
Read Me First

The L-478D/DR meters feature upgradeable firmware. This important advance makes them futurepoof and allows you obtain operational improvements or new features free of charge on the sekonic website.

  • Firmware upgrade is performed using the Sekonic Data Transfer Software (DTS) program available free of charge. Download the software here:
    http://www.sekonic.com/Support/Downloads/DTSSoftwareforMACandWindows.aspx
    NOTE: The CD included with the meter has an earlier version of the Data Transfer Software (3.04). Do not use this software. Please obtain the latest version (v3.05) from Sekonic.com.

Once downloaded,

  • Attach the meter to your computer using a standard, mini USB cable (not included with meter).
  • Press the L-478D/DR power button to see the USB indication on the meter screen.
  • Boot up the Data Transfer Software Program
  • Click the “Update Settings” tab and the “ Update Check” button when it appears.
  • If number in the “Current Version window is lower than the number in the “Latest Version” window, click on the “Update” button to upgrade the meter’s firmware to the latest version.

Updating will take approximately 8-10 minutes. Do not unplug the meter until indicated by the DTS software screen.

L-478D/DR: Battery operation

The L-478D/DR are packaged with High Power Manganese AAA-type batteries. These batteries provide power enough to familiarize yourself with the many features of the meter. Sekonic recommends using Alkaline or Lithium AAA-type batteries for normal operation as these provide extended life.


L-478D/DR Bundle: Read Me First

Find out how to use the X-Rite ColorChecker Passport with Sekonic Gray Balance Card and Sekonic’s Data Transfer Software exposure calibration system.

NOTE: If you intend to use only the incident light measuring mode when measuring light with your L-478-series meter, you can still use Sekonic’s DTS system to calibrate the meter to a camera’s middle gray tone for best exposures. Using the Incident-Only mode does not require purchase or use of the L-478 meter’s accessory 5-degree Viewfinder.